Feng Ruohang 6613c2a3cb test: pin the external fixtures and run the suites against the silo binary
The test and verification scripts invoked ./minio and pulled their tooling from
upstream infrastructure with no integrity check. Every `curl | tar` of a client
or an old server binary was an unverified execution path in a script that
regularly runs as a privileged user, and several fetched a floating "latest".

Two installers replace all of it:

- install-mcli.sh resolves a pinned pgsty/mc release, downloads the archive and
  its checksum manifest, requires exactly one valid manifest entry for the
  asset, verifies it, and installs. MCLI_BIN with a mandatory MCLI_SHA256 lets
  an offline or air-gapped run supply its own binary, still checksum-checked.
- install-verified-fixture.sh takes source, expected SHA-256 and target, and
  refuses anything that does not match. Sources may be a URL or a local file.

Every script that previously downloaded mc now calls install-mcli.sh. The three
places that genuinely need an upstream artifact - the old MinIO server binary
for the LDAP IAM upgrade-import test, the 2021 mc for the three-site
replication test, and the functional-tests.sh fixture - go through
install-verified-fixture.sh with the digest recorded inline. Those dl.min.io
URLs remain on purpose: they are historical upstream artifacts needed to prove
upgrade compatibility, and they are now pinned and verified rather than
trusted.

The scripts otherwise switch to ./silo, silo.service, the silo container and
compose service names, and SILO_CONFIG_DIR. run-multi-site-minio-idp.sh is
renamed to run-multi-site-silo-idp.sh with the Makefile target following.
buildscripts/minio-upgrade.sh keeps its name and its `minio server` argv - it
exists to test the MinIO-to-Silo upgrade, so the old side must stay old - but
it is now pinned to an image digest rather than a tag, and its `docker system
prune` and `docker volume prune` calls are removed. Those ran unfiltered
against the developer's whole Docker installation; the resiliency tests had the
same problem and lose their prune and `docker ps -q` sweeps too.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-06 08:48:58 +08:00

83 lines
1.9 KiB
Plaintext

[main]
summary=Maximum server performance for Silo
[vm]
transparent_hugepage=madvise
[sysfs]
/sys/kernel/mm/transparent_hugepage/defrag=defer+madvise
/sys/kernel/mm/transparent_hugepage/khugepaged/max_ptes_none=0
[cpu]
force_latency=1
governor=performance
energy_perf_bias=performance
min_perf_pct=100
[sysctl]
fs.xfs.xfssyncd_centisecs=72000
net.core.busy_read=50
net.core.busy_poll=50
kernel.numa_balancing=1
# Do not use swap at all
vm.swappiness=0
vm.vfs_cache_pressure=50
# Start writeback at 3% memory
vm.dirty_background_ratio=3
# Force writeback at 10% memory
vm.dirty_ratio=10
# Quite a few memory map
# areas may be consumed
vm.max_map_count=524288
# Default is 500000 = 0.5ms
kernel.sched_migration_cost_ns=5000000
# stalled hdd io threads
kernel.hung_task_timeout_secs=85
# network tuning for bigger throughput
net.core.netdev_max_backlog=250000
net.core.somaxconn=16384
net.ipv4.tcp_syncookies=0
net.ipv4.tcp_max_syn_backlog=16384
net.core.wmem_max=4194304
net.core.rmem_max=4194304
net.core.rmem_default=4194304
net.core.wmem_default=4194304
net.ipv4.tcp_rmem="4096 87380 4194304"
net.ipv4.tcp_wmem="4096 65536 4194304"
# Reduce CPU utilization
net.ipv4.tcp_timestamps=0
# Increase throughput
net.ipv4.tcp_sack=1
# Low latency mode for TCP
net.ipv4.tcp_low_latency=1
# The following variable is used to tell the kernel how
# much of the socket buffer space should be used for TCP
# window size, and how much to save for an application buffer.
net.ipv4.tcp_adv_win_scale=1
# disable RFC2861 behavior
net.ipv4.tcp_slow_start_after_idle = 0
# Fix faulty network setups
net.ipv4.tcp_mtu_probing=1
net.ipv4.tcp_base_mss=1280
# Disable ipv6
net.ipv6.conf.all.disable_ipv6=1
net.ipv6.conf.default.disable_ipv6=1
net.ipv6.conf.lo.disable_ipv6=1
[bootloader]
# Avoid firing timers for all CPUs at the same time. This is irrelevant for
# full nohz systems
cmdline=skew_tick=1